Image:Thermocouple0002.jpg|thumb|right|Thermocouple connected to a multimeter displaying room temperature in Celsius|°C.
+
An article about <nowiki>[[Thermocouple]]</nowiki> exists at [[http://en.wikipedia.org/wiki/Thermocouple '''Wikipedia''']]
 
 
A '''thermocouple''' is a device consisting of two different conductors (usually metal alloys) that produce a voltage, proportional to a temperature difference, between either ends of the two conductors. Thermocouples are a widely used type of list of temperature sensors|temperature sensor for measurement and control<ref name="tcs_html">
 
{{cite web |url=http://www.temperatures.com/tcs.html |work=Temperatures.com |title=Thermocouple temperature sensors |accessdate=2007-11-04}}</ref> and can also be used to convert a temperature gradient into electricity. They are inexpensive,<ref name="Ramsden2000">{{cite journal |author=Ramsden, Ed |date=September 1, 2000 |title=Temperature measurement |journal=Sensors |url=http://www.sensorsmag.com/sensors/temperature/temperature-measurement-1030  |accessdate=2010-02-19}}</ref> interchangeable, are supplied with standard connectors, and can measure a wide range of temperatures. In contrast to most other methods of temperature measurement, thermocouples are self powered and require no external form of excitation. The main limitation with thermocouples is accuracy and system errors of less than one degree Celsius (C) can be difficult to achieve.<ref name="tctable.html">{{cite web |title=Technical Notes: Thermocouple Accuracy |work=IEC 584-2(1982)+A1(1989) |url=http://www.microlink.co.uk/tctable.html |accessdate=2010-04-28}}</ref>
 
 
 
Any junction of dissimilar metals will produce an electric potential related to temperature. Thermocouples for practical measurement of temperature are junctions of specific alloys which have a predictable and repeatable relationship between temperature and voltage.  Different alloys are used for different temperature ranges.  Properties such as resistance to corrosion may also be important when choosing a type of thermocouple.  Where the measurement point is far from the measuring instrument, the intermediate connection can be made by extension wires which are less costly than the materials used to make the sensor. Thermocouples are usually standardized against a reference temperature of 0 degrees Celsius; practical instruments use electronic methods of cold-junction compensation to adjust for varying temperature at the instrument terminals. Electronic instruments can also compensate for the varying characteristics of the thermocouple, and so improve the precision and accuracy of measurements.
 
 
 
Thermocouples are widely used in science and industry; applications include temperature measurement for kilns, gas turbine exhaust, Diesel engine|diesel engines, and other industrial processes.
 
 
 
File:Thermocouple circuit.svg|thumb|400px|right| A thermocouple measuring circuit with a heat source, cold junction and a measuring instrument.
 
 
 
==Principle of operation==
 
{{main|Seebeck effect}}
 
In 1821, the Germany|German–Estonian physicist Thomas Johann Seebeck discovered that when any conductor is subjected to a thermal gradient, it will generate a voltage. This is now known as the thermoelectric effect or Seebeck effect. Any attempt to measure this voltage necessarily involves connecting another conductor to the "hot" end. This additional conductor will then also experience the temperature gradient, and develop a voltage of its own which will oppose the original. Fortunately, the magnitude of the effect depends on the metal in use. Using a dissimilar metal to complete the circuit creates a circuit in which the two legs generate different voltages, leaving a small difference in voltage available for measurement. That difference increases with temperature, and is between 1 and 70 microvolts per degree Celsius (µV/°C) for standard metal combinations.
 
 
 
The voltage is not generated at the junction of the two metals of the thermocouple but rather along that portion of the length of the two dissimilar metals that is subjected to a temperature gradient. Because both lengths of dissimilar metals experience the same temperature gradient, the end result is a measurement of the difference in temperature between the thermocouple junction and the reference junction.
 
 
 
===Laws for thermocouple circuits===
 
The properties of thermoelectric junctions with varying temperatures and compositions can be summarized in three laws describing the behaviour of thermocouple circuits.
 
==== Homogeneous material====
 
A thermoelectric current cannot be sustained in a circuit of a single homogeneous material by the application of heat alone, regardless of how it might vary in cross section. In other words, temperature changes in the wiring between the input and output do not affect the output voltage, provided all wires are made of the same materials as the thermocouple.  No current flows in the circuit made of a single metal by the application of heat alone.
 
 
 
====Intermediate materials====
 
The algebraic sum of the thermoelectric Electromotive force|EMFs in a circuit composed of any number of dissimilar materials is zero if all
 
of the junctions are at a uniform temperature. So If a third metal is inserted in either wire and if the two new junctions are at the same temperature, there will be no net voltage generated by the new metal.
 
 
 
====Successive or intermediate temperatures====
 
If two dissimilar homogeneous materials produce thermal EMF1 when the junctions are at T1 and T2 and produce thermal EMF2 when the junctions are at T2 and T3, the EMF generated when the junctions are at T1 and T3 will be EMF1 + EMF2, provided T1<T2<T3.
 
 
 
==Practical use==
 
===Voltage–temperature relationship===
 
{| class="wikitable" align="right" border="1"
 
|+ Polynomial Coefficients 0-500 °C<ref name=ITSdatabase>{{ cite web|url=http://srdata.nist.gov/its90/main/|title=NIST ITS-90 Thermocouple Database}}</ref>
 
| '''<math>n</math>''' || '''<math>a_n</math> (for Type K)'''
 
|-
 
|  1|| 25.08355
 
|-
 
|  2|| 7.860106x10<sup>-2</sup>
 
|-
 
|  3|| -2.503131x10<sup>-1</sup>
 
|-
 
|  4|| 8.315270x10<sup>-2</sup>
 
|-
 
|  5|| -1.228034x10<sup>-2</sup>
 
|-
 
|  6|| 9.804036x10<sup>-4</sup>
 
|-
 
|  7|| -4.413030x10<sup>-5</sup>
 
|-
 
|  8|| 1.057734x10<sup><sup>-6</sup>
 
|-
 
|  9|| -1.052755x10<sup><sup>-8</sup>
 
|}
 
 
 
For typical metals used in thermocouples, the output voltage increases almost linearly with the temperature difference (?T) over a bounded range of temperatures.  For precise measurements or measurements outside of the linear temperature range, non-linearity must be corrected.  The nonlinearity|nonlinear relationship between the temperature difference (?T) and the output voltage (mV) of a thermocouple can be approximated by a polynomial:
 
 
 
<math>\Delta T = \sum_{n = 0}^N a_n v^n</math>
 
 
 
The coefficients a<sub>n</sub> are given for n from 0 to between 5 and 13 depending upon the metals. In some cases better accuracy is obtained with additional non-polynomial terms.<ref name=ITSdatabase/> A database of voltage as a function of temperature, and coefficients for computation of temperature from voltage and vice-versa for many types of thermocouple is available online.<ref name=ITSdatabase/>
 
 
 
In modern equipment the equation is usually implemented in a digital controller or stored in a look-up table;<ref name="Baker2000">{{cite journal |author=Baker, Bonnie C. |date=September 1, 2000 |title=Designing the embedded temperature circuit to meet the system's requirements |journal=Sensors |url=http://www.sensorsmag.com/sensors/temperature/designing-embedded-temperature-circuit-meet-system039s-requi-1089?print=1 |accessdate=2010-04-26}}</ref> older devices use analog circuits.
 
 
 
Piece-wise linear approximations are an alternative to polynomial corrections.<ref>[http://www.mstarlabs.com/sensors/thermocouple-calibration.html "''Thermocouple Calibration'', Microstar Laboratories"]</ref>
 
 
 
===Cold junction compensation ===
 
 
 
Thermocouples measure the temperature difference between two points, not absolute temperature. To measure a single temperature one of the junctions—normally the cold junction—is maintained at a known reference temperature, and the other junction is at the temperature to be sensed.
 
 
 
Having a junction of known temperature, while useful for laboratory calibration, is not convenient for most measurement and control applications. Instead, they incorporate an artificial cold junction using a thermally sensitive device such as a thermistor or diode to measure the temperature of the input connections at the instrument, with special care being taken to minimize any temperature gradient between terminals. Hence, the voltage from a known cold junction can be simulated, and the appropriate correction applied. This is known as cold junction compensation.  Some integrated circuits such as the LT1025 are designed to output a compensated voltage based on thermocouple type and cold junction temperature.
 
 
 
==Grades==
 
Thermocouple wire is available in several different metallurgical formulations per type, typically, in decreasing levels of accuracy and cost: special limits of error, standard, and extension grades.
 
 
 
Extension grade wires made of the same metals as a higher-grade thermocouple are used to connect it to a measuring instrument some distance away without introducing additional junctions between dissimilar materials which would generate unwanted voltages; the connections to the extension wires, being of like metals, do not generate a voltage.
 
 
 
In the case of platinum thermocouples, extension wire is a copper alloy, since it would be prohibitively expensive to use platinum for extension wires. The extension wire is specified to have a very similar thermal coefficient of Electromotive force|EMF to the thermocouple, but only over a narrow range of temperatures; this reduces the cost significantly.
 
 
 
The temperature-measuring instrument must have high input impedance to prevent any significant current draw from the thermocouple, to prevent a resistive voltage drop across the wire. Changes in metallurgy along the length of the thermocouple (such as termination strips or changes in thermocouple type wire) will introduce another thermocouple junction which affects measurement accuracy.
 
 
 
==Types==
 
Certain combinations of alloys have become popular as industry standards. Selection of the combination is driven by cost, availability, convenience, melting point, chemical properties, stability, and output. Different types are best suited for different applications. They are usually selected based on the temperature range and sensitivity needed. Thermocouples with low sensitivities (B, R, and S types) have correspondingly lower resolutions. Other selection criteria include the inertness of the thermocouple material, and whether it is magnetic or not. Standard thermocouple types are listed below with the positive electrode first, followed by the negative electrode.
 
 
 
===K===
 
 
 
Type K (chromel{90 percent nickel and 10 percent chromium}–alumel)(Alumel  consisting of 95% nickel, 2% manganese, 2% aluminium and 1% silicon) is the most common general purpose thermocouple with a sensitivity  of approximately 41&nbsp;µV/°C, chromel positive relative to alumel.<ref>Manual on the Use of Thermocouples in Temperature Measurements. ASTM, 1974</ref> It is inexpensive, and a wide variety of probes are available in its -200&nbsp;°C to +1350&nbsp;°C / -328&nbsp;°F to +2462&nbsp;°F range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic; a characteristic of thermocouples made with magnetic material is that they undergo a deviation in output when the material reaches its  Curie temperature | Curie point; this occurs for type K thermocouples at around 350 °C .
 
 
 
===E===
 
Type E (chromel–constantan)<ref name="Baker2000"/> has a high output (68&nbsp;µV/°C) which makes it well suited to cryogenic use. Additionally, it is non-magnetic.
 
 
 
===J===
 
Type J (iron–constantan) has a more restricted range than type K (-40 to +750&nbsp;°C), but higher sensitivity of about 55&nbsp;µV/°C.<ref name="Ramsden2000"/> The Curie point of the iron (770&nbsp;°C)<ref>Buschow, K. H. J.''Encyclopedia of materials : science and technology'', Elsevier, 2001 ISBN 0-08-043152-6, p. 5021 table 1</ref> causes an abrupt change in the characteristic, which determines the upper temperature limit.
 
 
 
===N===
 
Type N (Nicrosil–Nisil) (nickel-chromium-silicon/nickel-silicon) thermocouples are suitable for use between -270 °C and 1300 °C owing to its stability and oxidation resistance. Sensitivity is about 39&nbsp;µV/°C at 900 °C, slightly lower compared to type K. 
 
 
 
Designed at the Defence Science and Technology Organisation (DSTO), Australia, by Noel A Burley, type N thermocouples overcome the three principal characteristic types and causes of thermoelectric instability in the standard base-metal thermoelement materials:<ref>Noel A Burley [http://tcomega.com/temperature/Z/pdf/z041-044.pdf Nicrosil/Nisil Type N Thermocouples]. tcomega.com</ref>
 
 
 
1. A gradual and generally cumulative drift in thermal EMF on long exposure at elevated temperatures. This is observed in all base-metal thermoelement materials and is mainly due to compositional changes caused by oxidation, carburization or neutron irradiation that can produce transmutation in nuclear reactor environments. In the case of type K, manganese and aluminium elements from the KN (negative) wire migrate to the KP (positive) wire resulting in a down-scale drift due to chemical contamination. This effect is cumulative and irreversible. 
 
 
 
2. A short-term cyclic change in thermal EMF on heating in the temperature range ca. 250–650 ºC, which occurs in types K, J, T and E thermocouples. This kind of EMF instability is associated with structural changes like magnetic short range order.   
 
 
 
3. A time-independent perturbation in thermal EMF in specific temperature ranges. This is due to composition-dependent magnetic transformations that perturb the thermal EMFs in type K thermocouples in the range ca. 25-225 ºC, and in type J above 730 ºC.
 
 
 
Nicrosil and Nisil thermocouple alloys show greatly enhanced thermoelectric stability relative to the other standard base-metal thermocouple alloys because their compositions substantially reduces the thermoelectric instability described above. This is achieved primarily by increasing component solute concentrations (chromium and silicon) in a base of nickel above those required to cause a transition from internal to external modes of oxidation, and by selecting solutes (silicon and magnesium) that preferentially oxidize to form a diffusion-barrier, and hence oxidation inhibiting films.
 
 
 
===Platinum types B, R, and S===
 
Types B, R, and S thermocouples use platinum or a platinum–rhodium alloy for each conductor. These are among the most stable thermocouples, but have lower sensitivity than other types, approximately 10&nbsp;µV/°C. Type B, R, and S thermocouples are usually used only for high temperature measurements due to their high cost and low sensitivity.
 
 
 
;'''B'''
 
Type B thermocouples use a platinum–rhodium alloy for each conductor. One conductor contains 30% rhodium while the other conductor contains 6% rhodium. These thermocouples are suited for use at up to 1800&nbsp;°C. Type B thermocouples produce the same output at 0&nbsp;°C and 42&nbsp;°C, limiting their use below about 50&nbsp;°C.
 
 
 
;'''R'''
 
Type R thermocouples use a platinum–rhodium alloy containing 13% rhodium for one conductor and pure platinum for the other conductor. Type R thermocouples are used up to 1600&nbsp;°C.
 
 
 
;'''S'''
 
Type S thermocouples are constructed using one wire of 90% Platinum and 10% Rhodium (the positive or "+" wire) and a second wire of 100% platinum (the negative or "-" wire).  Like type R, type S thermocouples are used up to 1600&nbsp;°C. In particular, type S is used as the standard of calibration for the melting point of gold (1064.43&nbsp;°C).
 
 
 
===T===
 
Type T (copper–constantan) thermocouples are suited for measurements in the -200 to 350&nbsp;°C range. Often used as a differential measurement since only copper wire touches the probes. Since both conductors are non-magnetic, there is no Curie point and thus no abrupt change in characteristics. Type T thermocouples have a sensitivity of about 43&nbsp;µV/°C.
 
 
 
===C===
 
Type C (tungsten 5% rhenium – tungsten 26% rhenium) thermocouples are suited for measurements in the 0&nbsp;°C to 2320&nbsp;°C range. This thermocouple is well-suited for vacuum furnaces at extremely high temperatures. It must never be used in the presence of oxygen at temperatures above 260 °C.
 
 
 
===M===
 
Type M thermocouples use a nickel alloy for each wire. The positive wire (20 Alloy) contains 18% molybdenum while the negative wire (19 Alloy) contains 0.8% cobalt. These thermocouples are used in vacuum furnaces for the same reasons as with type C. Upper temperature is limited to 1400&nbsp;°C. It is less commonly used than other types.
 
 
 
===Chromel-gold/iron===
 
In chromel-gold/iron thermocouples, the positive wire is chromel and the negative wire is gold with a small fraction (0.03–0.15 atom percent) of iron. It can be used for cryogenics|cryogenic applications (1.2–300 K and even up to 600 K). Both the sensitivity and the temperature range depends on the iron concentration. The sensitivity is typically around 15 µV/K at low temperatures and the lowest usable temperature varies between 1.2 and 4.2 K.
 
 
 
==Aging of thermocouples==
 
Thermoelements are often used at high temperatures and in reactive furnace atmospheres.
 
In this case the practical lifetime is limited by aging.
 
The thermoelectric coefficients of the wires in a thermocouple that is used to measure very high temperatures change with time, and the measurement voltage accordingly drops. The simple relationship between the temperature difference of the joints and the measurement voltage is only correct if each wire is homogeneous. With an aged thermocouple this is not the case. Also, the presence of a temperature gradient where the two metals meet can affect the measured voltage.  If an aged thermocouple is pulled partly out of the furnace, the aged parts from the region previously at high temperature enter the area of temperature gradient and the measurement error is significantly increased. However an aged thermocouple that is pushed deeper into the furnace gives a more accurate reading. {{Citation needed|date=September 2011}}
 
 
 
==Thermocouple comparison==
 
The table below describes properties of several different thermocouple types. Within the tolerance columns, T represents the temperature of the hot junction, in degrees Celsius. For example, a thermocouple with a tolerance of ±0.0025×T would have a tolerance of ±2.5&nbsp;°C at 1000&nbsp;°C.
 
 
 
{| class="wikitable"
 
|-
 
! Type
 
! Temperature range °C (continuous)
 
! Temperature range °C (short term)
 
! Tolerance class one (°C)
 
! Tolerance class two (°C)
 
! IEC Color code
 
! BS Color code
 
! ANSI Color code
 
|-
 
| K
 
| 0 to +1100
 
| -180 to +1300
 
| {{nobreak | ±1.5 between -40 °C and 375 °C}}<br />{{nobreak | ±0.004×T between 375 °C and 1000 °C}}
 
| {{nobreak | ±2.5 between -40 °C and 333 °C}}<br />{{nobreak | ±0.0075×T between 333 °C and 1200 °C}}
 
| Image:IEC Type K Thermocouple.svg|center|56px
 
| Image:BS Type K Thermocouple.svg|center|56px
 
| Image:MC 96.1 K Thermocouple Grade Color Code.svg|center|56px
 
|-
 
| J
 
| 0 to +750
 
| -180 to +800
 
| {{nobreak | ±1.5 between -40 °C and 375 °C}}<br />{{nobreak | ±0.004×T between 375 °C and 750 °C}}
 
| {{nobreak | ±2.5 between -40 °C and 333 °C}}<br />{{nobreak | ±0.0075×T between 333 °C and 750 °C}}
 
| Image:IEC Type J Thermocouple.svg|center|56px
 
| Image:BS Type J Thermocouple.svg|center|56px
 
| Image:MC 96.1 J Thermocouple Grade Color Code.svg|center|56px
 
|-
 
| N
 
| 0 to +1100
 
| -270 to +1300
 
| {{nobreak | ±1.5 between -40 °C and 375 °C}}<br />{{nobreak | ±0.004×T between 375 °C and 1000 °C}}
 
| {{nobreak | ±2.5 between -40 °C and 333 °C}}<br />{{nobreak | ±0.0075×T between 333 °C and 1200 °C}}
 
|  Image:IEC Type N Thermocouple.svg|center|56px
 
|  Image:BS Type N Thermocouple.svg|center|56px
 
| Image:MC 96.1 N Thermocouple Grade Color Code.svg|center|56px
 
|-
 
| R
 
| 0 to +1600
 
| -50 to +1700
 
| {{nobreak | ±1.0 between 0 °C and 1100 °C}}<br />{{nobreak | ±[1 + 0.003×(T - 1100)] between 1100 °C and 1600 °C}}
 
| {{nobreak | ±1.5 between 0 °C and 600 °C}}<br />{{nobreak | ±0.0025×T between 600 °C and 1600  °C}}
 
| Image:BS Type N Thermocouple.svg|center|56px
 
| Image:BS Type R Thermocouple.svg|center|56px
 
| Not defined.
 
|-
 
| S
 
| 0 to 1600
 
| -50 to +1750
 
| {{nobreak | ±1.0 between 0 °C and 1100 °C}}<br />{{nobreak | ±[1 + 0.003×(T - 1100)] between 1100 °C and 1600 °C}}
 
| {{nobreak | ±1.5 between 0 °C and 600 °C}}<br />{{nobreak | ±0.0025×T between 600 °C and 1600  °C}}
 
|
 
| Image:BS Type R Thermocouple.svg|center|56px
 
| Not defined.
 
|-
 
| B
 
| +200 to +1700
 
| 0 to +1820
 
| Not Available
 
| {{nobreak | ±0.0025×T between 600 °C and 1700 °C}}
 
| No standard use copper wire
 
| No standard use copper wire
 
| Not defined.
 
|-
 
| T
 
| -185 to +300
 
| -250 to +400
 
| {{nobreak | ±0.5 between -40 °C and 125 °C}}<br />{{nobreak | ±0.004×T between 125 °C and 350 °C}}
 
| {{nobreak | ±1.0 between -40 °C and 133 °C}}<br />{{nobreak | ±0.0075×T between 133 °C and 350 °C}}
 
| Image:IEC Type T Thermocouple.svg|center|56px
 
| Image:BS Type T Thermocouple.svg|center|56px
 
| Image:MC 96.1 T Thermocouple Grade Color Code.svg|center|56px
 
|-
 
| E
 
| 0 to +800
 
| -40 to +900
 
| {{nobreak | ±1.5 between -40 °C and 375 °C}}<br />{{nobreak | ±0.004×T between 375 °C and 800 °C}}
 
| {{nobreak | ±2.5 between -40 °C and 333 °C}}<br />{{nobreak | ±0.0075×T between 333 °C and 900 °C}}
 
| Image:IEC Type E Thermocouple.svg|center|56px
 
| Image:BS Type E Thermocouple.svg|center|56px
 
| Image:MC 96.1 E Thermocouple Grade Color Code.svg|center|56px
 
|-
 
| Chromel/AuFe
 
| -272 to +300
 
| n/a
 
| colspan=2 | Reproducibility 0.2% of the voltage; each sensor needs individual calibration.
 
|
 
|
 
|
 
|}
 
 
 
==Applications==
 
Thermocouples are suitable for measuring over a large temperature range, up to 2300 °C. They are less suitable for applications where smaller temperature differences need to be measured with high accuracy, for example the range 0–100 °C with 0.1 °C accuracy. For such applications thermistors, silicon band gap temperature sensors and resistance temperature detectors are more suitable. Applications include temperature measurement for kilns, gas turbine exhaust, Diesel engine|diesel engines, and other industrial processes.
 
 
 
===Steel industry===
 
Type B, S, R and K thermocouples are used extensively in the steel and iron industries to monitor temperatures and chemistry throughout the steel making process. Disposable, immersible, type S thermocouples are regularly used in the electric arc furnace process to accurately measure the temperature of steel before tapping. The cooling curve of a small steel sample can be analyzed and used to estimate the carbon content of molten steel.
 
 
 
===Heating appliance safety===
 
Many Natural gas|gas-fed heating appliances such as ovens and water heaters make use of a pilot light|pilot flame to ignite the main gas burner when required. If it goes out, gas may be released, which is a fire risk and a health hazard. To prevent this, some appliances use a thermocouple in a fail-safe circuit to sense when the pilot light is burning.
 
The tip of the thermocouple is placed in the pilot flame, generating a voltage which operates the supply valve which feeds gas to the pilot. So long as the pilot flame remains lit, the thermocouple remains hot, and the pilot gas valve is held open. If the pilot light goes out, the thermocouple temperature falls, causing the voltage across the thermocouple to drop and the valve to close.
 
Some combined main burner and pilot gas valves (mainly by Honeywell) reduce the power demand to within the range of a single universal thermocouple heated by a pilot (25mV open circuit falling by half with the coil connected to 10~12mV @ 0.2~0.25A typically) by sizing the coil to be able to hold the valve open against a light spring, only after the initial turning on force is provided by a the user pressing and holding a knob to compress the spring during first lighting. These systems are identifiable by the 'press and hold for x minutes' in the pilot lighting instructions. (The holding current requirement of such a valve is much less than a bigger solenoid designed for pulling the valve in from closed would require.) Special test sets are made to confirm the valve let-go and holding currents as an ordinary milliameter cannot be used as it introduces more resistance than the gas valve coil. Apart from testing the open circuit voltage of the thermocouple, and the near short-circuit DC continuity through the thermocouple gas valve coil, the easiest non-specialist test is substitution of a known good gas valve.
 
 
 
Some systems, known as millivolt control systems, extend the thermocouple concept to both open and close the main gas valve as well. Not only does the voltage created by the pilot thermocouple activate the pilot gas valve, it is also routed through a thermostat to power the main gas valve as well. Here, a larger voltage is needed than in a pilot flame safety system described above, and a thermopile is used rather than a single thermocouple. Such a system requires no external source of electricity for its operation and so can operate during a power failure, provided all the related system components allow for this. Note that this excludes common forced air furnaces because external power is required to operate the blower motor, but this feature is especially useful for un-powered convection heaters.
 
A similar gas shut-off safety mechanism using a thermocouple is sometimes employed to ensure that the main burner ignites within a certain time period, shutting off the main burner gas supply valve should that not happen.
 
 
 
Out of concern for energy wasted by the standing pilot, designers of many newer appliances have switched to an electronically controlled pilot-less ignition, also called intermittent ignition. With no standing pilot flame, there is no risk of gas buildup should the flame go out, so these appliances do not need thermocouple-based pilot safety switches. As these designs lose the benefit of operation without a continuous source of electricity, standing pilots are still used in some appliances. The exception is later model instantaneous (aka "tankless") water heaters that use the flow of water to generate the current required to ignite the gas burner, in conjunction with a thermocouple as a safety cut-off device in the event the gas fails to ignite, or the flame is extinguished.
 
 
 
===Thermopile radiation sensors===
 
{{see also|bolometer}}
 
Thermopiles are used for measuring the intensity of incident radiation, typically visible or infrared light, which heats the hot junctions, while the cold junctions are on a heat sink. It is possible to measure radiative intensity (physics)|intensities of only a few µW/cm<sup>2</sup> with commercially available thermopile sensors. For example, some laser power (physics)|power meters are based on such sensors.
 
 
 
===Manufacturing===
 
Thermocouples can generally be used in the testing of prototype electrical and mechanical apparatus. For example, switchgear under test for its current carrying capacity may have thermocouples installed and monitored during a heat run test, to confirm that the temperature rise at rated current does not exceed designed limits.
 
 
 
===Power production===
 
{{main|Thermoelectric generator }}
 
A thermocouple can produce current to drive some processes directly, without the need for extra circuitry and power sources. For example, the power from a thermocouple can activate a valve when a temperature difference arises. The electrical energy generated by a thermocouple is converted from the heat which must be supplied to the hot side to maintain the electric potential. A continuous transfer of heat is necessary because the current flowing through the thermocouple tends to cause the hot side to cool down and the cold side to heat up (the Peltier effect).
 
 
 
Thermocouples can be connected in series to form a thermopile, where all the hot junctions are exposed to a higher temperature and all the cold junctions to a lower temperature. The output is the sum of the voltages across the individual junctions, giving larger voltage and power output. In a radioisotope thermoelectric generator, the radioactive decay of transuranic elements as a heat source has been used to power spacecraft on missions too far from the Sun to use solar power.
 
 
 
Thermopiles heated by kerosene lamps were used to run batteryless radio  receivers in isolated areas.<ref>{{cite book|author=Reed Business Information|title=New Scientist|url=http://books.google.com/books?id=B-ve-ZR6QRIC&pg=PA67|accessdate=28 May 2012|date=10 January 1974|publisher=Reed Business Information|pages=67–|id={{ISSN|02624079}}}}</ref> There are commercially produced lanterns that use the heat from a candle to run several light-emitting diodes, and thermoelectrically-powered fans to improve air circulation and heat distribution in wood stoves.
 
 
 
===Process plants===
 
Chemical production and petroleum refineries will usually employ computers for logging and limit testing the many temperatures associated with  a process, typically numbering in the hundreds. For such cases a number of thermocouple leads will be brought to a common reference block (a large block of copper) containing the second thermocouple of each circuit. The temperature of the block is in turn measured by a thermistor. Simple computations are used to determine the temperature at each measured location.
 
 
 
==See also==
 
*Bolometer
 
*Giuseppe Domenico Botto
 
*Resistance thermometer
 
*Thermistor
 
*List of sensors
 
*International Temperature Scale of 1990
 
 
 
==References==
 
{{reflist}}
 
 
 
==External links==
 
*Jim Williams (analog designer)|Jim Williams, [http://cds.linear.com/docs/Application%20Note/an28f.pdf "Thermocouple measurement"], Linear Technology Application Note 28, February 1988.
 
*[http://www.msm.cam.ac.uk/UTC/thermocouple/pages/ThermocouplesOperatingPrinciples.html Thermocouple Operating Principle – University Of Cambridge]
 
*[http://www.msm.cam.ac.uk/UTC/thermocouple/pages/Drift.html Thermocouple Drift – University Of Cambridge]
 
*[http://www.analog.com/library/analogDialogue/archives/44-10/thermocouple.pdf Two Ways to Measure Temperature Using Thermocouples]
 
*[http://www.peaksensors.co.uk/designguide.html Thermocouple design guide]
 
*[http://www.isomil.de/en/mineral-insulated-cable.htm Mineral-Insulated Thermocouple Know-How]
 
*[http://www.thermalcorp.com/documents/TCCHART.pdf Thermocouple Color Code Chart and Specifications]
 
*[http://www.ecd.com/news/articles/tc-attachment.asp Thermocouple Attachment – A Primer]
 
*[http://www.keyosens.com/tcletter.php Thermocouple design]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_J_table.pdf J type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_K_table.pdf K type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_T_table.pdf T type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_E_table.pdf E type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_N_table.pdf N type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_R_table.pdf R type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_S_table.pdf S type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_type_B_table.pdf B type thermocouple table]
 
*[http://www.tempsens.com/thermocouple_pdf/Thermocouple_Reference_data.pdf Thermocouple Reference data]
 
<!--PLEASE DO NOT ADD YOUR COMPANY TO THIS LIST. IT IS AGAINST WIKIPEDIA GUIDELINES -->
 
 
 
Category:Heating, ventilating, and air conditioning
 
Category:Thermometers
 
Category:Sensors
 
 
 
ar:?????? ??????
 
bs:Termopar
 
bg:???????????
 
ca:Termoparell
 
cs:Termoclánek
 
de:Thermoelement
 
et:Termopaartajur
 
es:Termopar
 
eo:Termoparo
 
fa:????????
 
fr:Thermocouple
 
ko:???
 
hi:????????
 
id:Termokopel
 
it:Termocoppia
 
he:??? ????
 
kk:?????????
 
ml:???????????
 
nl:Thermokoppel
 
ja:???
 
pl:Termopara
 
pt:Termopar
 
ro:Termocuplu
 
ru:?????????
 
simple:Thermocouple
 
sl:Termopar
 
fi:Termopari
 
sv:Termoelement
 
ta:????????? ??????
 
tr:Termokupl
 
uk:?????????
 
zh:???
 

Revision as of 18:25, 2 June 2012

An article about [[Thermocouple]] exists at [Wikipedia]